Alcázar Solar

Needs attention

Castilla-La Mancha · Solar PV · 35 MW installed · 4 technicians · manager Thomas Winter

Output now

5.0 MW

Load factor

14 %

Energy today

58 MWh

Availability

95.7 %

Producing

14 / 18

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

4.2 m/s SE

Irradiance

301 W/m²

Temperature

21.3 °C

Cloud cover

10 %

Conditions

Clear

Substation

Alcázar SE 220 kV

Voltage

219.0 kV

Frequency

50.021 Hz

Power factor

0.977

Curtailment

6 %

Day-ahead price

91.41 €/MWh

Assets

18 assets on site. Open one for its live 3D view.

Power flow

Tracker block

PV-01

Soltec SF7 · 2.4 MWp

Producing
13%

Output

0.30 MW

Today

4.0 MWh

Availability

94.8 %

Tracker block

PV-02

Nextracker NX Horizon · 4.0 MWp

Producing
22%

Output

0.87 MW

Today

6.8 MWh

Availability

95.0 %

Tracker block

PV-03

Nextracker NX Horizon · 2.4 MWp

Producing
15%

Output

0.35 MW

Today

3.9 MWh

Availability

93.8 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
21%

Output

0.50 MW

Today

4.1 MWh

Availability

98.3 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
22%

Output

0.71 MW

Today

5.5 MWh

Availability

97.3 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Standby
0%

Output

0.00 MW

Today

6.6 MWh

Availability

94.4 %

Tracker block

PV-07

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

4.3 MWh

Availability

97.3 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
12%

Output

0.29 MW

Today

5.0 MWh

Availability

93.7 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Curtailed
14%

Output

0.33 MW

Today

2.4 MWh

Availability

94.5 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
17%

Output

0.67 MW

Today

6.1 MWh

Availability

93.9 %

Tracker block

PV-11

Nextracker NX Horizon · 3.2 MWp

Producing
22%

Output

0.70 MW

Today

5.0 MWh

Availability

97.4 %

Tracker block

PV-12

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
14%

Output

0.33 MW

Today

3.8 MWh

Availability

94.0 %

Inverter skid

INV-01

Huawei SUN2000-215KTL · 3.1 MVA

Producing
13%

Output

0.39 MW

Today

4.7 MWh

Availability

95.1 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 5.0 MVA

Producing
14%

Output

0.69 MW

Today

7.4 MWh

Availability

99.1 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 4.6 MVA

Producing
20%

Output

0.92 MW

Today

7.1 MWh

Availability

98.0 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
23%

Output

1.14 MW

Today

8.0 MWh

Availability

94.9 %

Inverter skid

INV-05

Sungrow SG3125HV-MV · 5.0 MVA

Fault
0%

Output

0.00 MW

Today

8.8 MWh

Availability

94.8 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
20%

Output

0.91 MW

Today

9.4 MWh

Availability

96.1 %

Alarms
Site alarms
Most recent events from this site's assets.

Transformer oil level low

INV-05· 11-16 14:00
Medium

DC insulation resistance low

INV-05· 11-16 11:03
Medium

Row stowed – high wind

PV-10· 11-16 04:56
Low

Grid voltage out of band

INV-05· 11-16 04:45
Medium

Grid voltage out of band

INV-01· 11-15 23:57
Medium

Tracker stuck – motor current high

PV-01· 11-15 17:12
Low