Altiplano Híbrido

Needs attention

Murcia · Wind + solar + storage · 74 MW installed · 8 technicians · manager John Ingram

Output now

3.8 MW

Load factor

5 %

Energy today

143 MWh

Availability

97.1 %

Producing

21 / 29

Open alarms

10

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

8.5 m/s W

Irradiance

180 W/m²

Temperature

22.3 °C

Cloud cover

67 %

Conditions

Partly cloudy

Substation

Yecla SE 220 kV

Voltage

220.0 kV

Frequency

50.023 Hz

Power factor

0.992

Curtailment

7 %

Day-ahead price

105.77 €/MWh

Assets

29 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

8.9 MWh

Wind

9.7 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 4.2 MW

Producing
14%

Output

0.61 MW

Today

11.5 MWh

Wind

7.3 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
23%

Output

0.95 MW

Today

9.4 MWh

Wind

8.2 m/s

Wind turbine

WTG-04

Vestas V150-4.2 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

11.1 MWh

Wind

5.3 m/s

Wind turbine

WTG-05

Vestas V150-4.2 · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

8.9 MWh

Wind

5.3 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
23%

Output

1.16 MW

Today

15.5 MWh

Wind

8.1 m/s

Tracker block

PV-01

Nextracker NX Horizon · 2.4 MWp

Producing
18%

Output

0.43 MW

Today

4.3 MWh

Availability

96.3 %

Tracker block

PV-02

Soltec SF7 · 2.4 MWp

Producing
13%

Output

0.30 MW

Today

4.0 MWh

Availability

99.2 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
18%

Output

0.42 MW

Today

3.5 MWh

Availability

93.3 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
27%

Output

1.07 MW

Today

7.3 MWh

Availability

97.5 %

Tracker block

PV-05

Soltec SF7 · 2.4 MWp

Producing
24%

Output

0.57 MW

Today

4.2 MWh

Availability

93.0 %

Tracker block

PV-06

Soltec SF7 · 4.0 MWp

Producing
19%

Output

0.77 MW

Today

7.4 MWh

Availability

95.5 %

Tracker block

PV-07

Soltec SF7 · 2.4 MWp

Producing
22%

Output

0.53 MW

Today

4.8 MWh

Availability

99.5 %

Tracker block

PV-08

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Maintenance
0%

Output

0.00 MW

Today

4.3 MWh

Availability

95.8 %

Tracker block

PV-09

Nextracker NX Horizon · 3.2 MWp

Producing
22%

Output

0.69 MW

Today

5.3 MWh

Availability

99.7 %

Tracker block

PV-10

Soltec SF7 · 4.0 MWp

Producing
24%

Output

0.96 MW

Today

7.5 MWh

Availability

94.5 %

Tracker block

PV-11

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
19%

Output

0.76 MW

Today

7.6 MWh

Availability

98.7 %

Tracker block

PV-12

Soltec SF7 · 3.2 MWp

Curtailed
8%

Output

0.26 MW

Today

3.0 MWh

Availability

98.7 %

Tracker block

PV-13

Soltec SF7 · 4.0 MWp

Fault
0%

Output

0.00 MW

Today

7.1 MWh

Availability

96.8 %

Tracker block

PV-14

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
13%

Output

0.50 MW

Today

7.5 MWh

Availability

97.3 %

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Maintenance
0%

Output

0.00 MW

Today

8.2 MWh

Availability

96.9 %

Inverter skid

INV-02

Sungrow SG3125HV-MV · 3.1 MVA

Producing
22%

Output

0.67 MW

Today

5.0 MWh

Availability

96.6 %

Inverter skid

INV-03

Huawei SUN2000-215KTL · 5.0 MVA

Producing
29%

Output

1.43 MW

Today

10.7 MWh

Availability

99.4 %

Inverter skid

INV-04

Huawei SUN2000-215KTL · 3.1 MVA

Curtailed
4%

Output

0.12 MW

Today

3.5 MWh

Availability

95.4 %

Inverter skid

INV-05

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
16%

Output

0.73 MW

Today

9.0 MWh

Availability

98.5 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 4.6 MVA

Producing
20%

Output

0.92 MW

Today

9.8 MWh

Availability

99.5 %

Inverter skid

INV-07

SMA Sunny Central 4600 UP · 4.6 MVA

Producing
22%

Output

1.00 MW

Today

11.3 MWh

Availability

98.7 %

Battery container

BESS-01

CATL EnerOne+ · 5.0 MW

Producing
69%

Output

3.45 MW

Today

0.0 MWh

State of charge

84 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
70%

Output

2.73 MW

Today

0.0 MWh

State of charge

84 %

Alarms
Site alarms
Most recent events from this site's assets.

Pitch system hydraulic pressure low

WTG-01· 11-16 14:29
Medium

Row stowed – high wind

PV-03· 11-16 14:27
Medium

Rack isolated by BMS

BESS-01· 11-16 11:33
Low

Generator winding temperature high

WTG-05· 11-16 08:05
Low

Soiling loss above threshold

PV-13· 11-16 02:50
High

Soiling loss above threshold

PV-08· 11-15 23:30
Low

Anemometer signal lost

WTG-04· 11-15 22:09
Low

Soiling loss above threshold

PV-13· 11-15 21:46
High